Escalator Specifications
CZPT configuration | |
Inclination (°) | thirty(35) |
Action width (mm) | 600/800/1000 |
Horizontal actions | 2/two three/three(for 30°), two/2 for 35° |
Velocity(m/s) | .5 |
Motor power | 8/11/15KW |
Handrail bracket | Stainless metal |
Rise height for 600 | 3000≤H≤6000/ 6000≤H≤7200 |
Increase height for 800 | 3000≤H≤4800/4800≤H≤6000/6000≤H≤6400/6400≤H≤7200 |
Rise height for a thousand | 3000≤H≤4800/4800≤H≤6000/6000≤H≤6400/6400≤H≤7200 |
Engineering Rewards
one.VVVF generate
two.Secure security technique
3.Ideal working overall performance
four.Innovative control method(German engineering)
5.Comfortable and efficient
6.Decrease sounds and strength-preserving
Security Features
one.Absence of section, mistake period protection:
If lack of stage (transferring-wander) will or eror section has been checked out, the escalator automatically stop the procedure.
2.Motor above-Ioad protection:
When the recent exceeds fifteen% of the present score, the escalator will automatically slop the operation.
3.CZPTal equipment loop safety:
It gives the computerized circuit disconnecting device to defend the circuit and mains parts of the escalator (shifting-stroll).
four.Handrail inlet protection:
When some foreign compound has been clipped in the handrail inlet. the escalator (transferring-stroll) will immediately slop the operation.
5.Comb plate safety unit:
When some international compound has been clipped in or amongst the combs.the escalator (shifting-stroll) will routinely quit the procedure.
six.Step sagging security unit:
When there is irregular step bending, the escalator (moving-stroll) will end the procedure just before the step coming into into the comb plate
seven.Damaged travel-chain security unit:
When the drive-chain has been over-stretched or it is damaged, the escalator (moving-wander) will instantly quit the procedure
eight.Damaged action chain security:
When the phase (plate) chain has been in excess of-stretched or it is broken, the escalator (moving walk) will automatically slop the operation.
nine.More than-velocity safety:
When there is in excess of-speed to the escalator (shifting walk),it will routinely quit the operation.
ten.Path reversal security:
When it comes the accidental reve rsal of the path of journey, the escalator (shifting wander) will immediately quit the operation.
11.Security line:
The yellow synthetic resin safety line is located in the entrance placement and two sides of the escalator tread so that the travellers will not tread in-among the edge of the adjacent stage and the team lengthened skirt panel. The security line on both sides of the step is higher than the tread area. (The moving-wander offers the selective yellow spray-palmed stability line.)