Escalator Part Chain
ISO Chain No. |
Pitch (mm) |
Roller Dia (mm) |
Width in between inner plates (mm) |
Pin Dia (mm) |
Inner Plate Depth(mm) |
Transverse Pitch (mm) |
Ultimate tensile power (kN) |
Average tensile toughness (kN) |
Weight per meter (kg/m) |
16A-2F | 25.4 | fifteen.88 | 15.75 | 7.92 | 24.thirteen | 29.29 | 111.2 | 143 | five.15 |
16B-2F | 25.four | 15.88 | 17.02 | 8.28 | 21.08 | 31.88 | 106 | 126.five | five.42 |
20A-2F | 31.seventy five | 19.05 | eighteen.nine | 9.53 | 30.18 | 35.76 | 173.5 | 215.6 | seven.8 |
20B-2F | 31.75 | 19.05 | 19.fifty eight | ten.19 | 26.forty two | 36.45 | a hundred and seventy | 210 | 7.two |
Escalator generate chain is utilizing for travel the escalator to go upwards CZPT sliding down.The push chain is usually inside the generate side plate.
Escalator driving system mainly consists of driving sprocket, cascade sprocket, handrail driving sprocket, primary shaft and brake wheel or ratchet wheel, and so on.
And it is set up in the leading device area on the escalator,which is the higher element of the roof that you take for the escalator.
Escalator reversing chain
Escalator Handrail Reversing chain in seventeen back links,19 backlinks,21 hyperlinks.
The main part of escalator:
1.Carries technique
2.Driving method
three.Ladder technique
four.Safety system
5.CZPTal program
Our benefits:
Strength saving–Successful mainframe and classic system and VVVF technological innovation.
Basic safety–Stainless metal step,Rigorous developed protection device and buffering method.
one.VVVF drive
two.Steady protection system
three.Ideal operating performance
four.Sophisticated control technique(German technologies)
5.Comfortable and effective
six.Reduce noise and energy-preserving
Protection Functions
one.Absence of section, mistake section protection:
If deficiency of stage (moving-walk) will or eror stage has been checked out, the escalator routinely stop the operation.
2.Motor above-Ioad safety:
When the existing exceeds 15% of the present ranking, the escalator will immediately slop the procedure.
three.CZPTal equipment loop defense:
It gives the computerized circuit disconnecting unit to safeguard the circuit and mains components of the escalator (relocating-walk).
4.Handrail inlet safety:
When some foreign compound has been clipped in the handrail inlet. the escalator (transferring-stroll) will immediately slop the operation.
five.Comb plate safety unit:
When some overseas compound has been clipped in or among the combs.the escalator (shifting-stroll) will routinely quit the operation.
6.Phase sagging safety unit:
When there is abnormal step bending, the escalator (moving-walk) will quit the procedure prior to the step getting into into the comb plate
seven.Broken generate-chain security gadget:
When the travel-chain has been more than-stretched or it is broken, the escalator (shifting-walk) will immediately end the operation
eight.Broken phase chain protection:
When the step (plate) chain has been more than-stretched or it is broken, the escalator (moving stroll) will routinely slop the operation.
9.Above-speed protection:
When there is more than-speed to the escalator (relocating walk),it will immediately stop the operation.
10.Path reversal safety:
When it will come the accidental reve rsal of the course of journey, the escalator (moving wander) will instantly cease the operation.
eleven.Stability line:
The yellow artificial resin protection line is situated in the entrance place and two sides of the escalator tread so that the travellers will not tread in-in between the edge of the adjacent phase and the team lengthened skirt panel. The stability line on each sides of the stage is greater than the tread surface. (The moving-stroll offers the selective yellow spray-palmed security line.)
About CZPT